"Please refer to the 19 error codes and their troubleshooting methods below to resolve the issue."
Error Codes | Meaning | Troubleshooting |
301, 302, 303, 304, 305 | Problem with heater or temperature sensor in nozzle | ① Reboot the machine, Reinstall the nozzle ② Nozzle replacement |
312, 313, 314 | Problem with leveling sensor detection | ① Check the bed installation ② Replace leveling sensor |
321 | Nozzle fan problem occurred |
① Check and remove nozzle fan debris ② Replace nozzle fan |
325 | Cooling fan problem | ① Check and remove cooling fan debris ② Renew cooling fan |
341 | Nozzle 1 and nozzle 2 are installed in a combination that cannot be used together. | After power off, reattach with available nozzle combinations |
343 | Nozzle data recognition failure | ① Reboot the machine, reinstall the nozzle ② Nozzle replacement |
351, 353, 354, 355 | Bed temperature problem | ① Reboot the machine ② Check the chamber heater ③ Replace bed heater |
381, 382, 383, 384 | Main fan malfunction | ① Check and remove foreign substances from the main fan ② Replace the main fan |
390, 391, 392, 393, 394 | Chamber heater or temperature sensor problem | ① Reboot the machine ② Replace chamber heater, temperature sensor, or harness |
396, 397, 398, 399 | Chamber fan malfunction | ① Check and remove chamber fan debris ② Fan replacement |
401 | Filament feeding problem during printing | Refer to 5-3 of User Manual to troubleshoot the problem |
405, 406 | Filament is exhausted or broken | Remove residual filaments and load new filaments |
408 | Gcode is out of printable range | Check 3D model and Gcode |
411, 412, 413 | Filament transfer problem during loading | After removing the filament, check for debris or dust inside the path. |
422, 423 | Filament transfer problem during unloading operation | Check for debris or dust inside the path after removing the filament |
431, 432, 433, 434, 435 | Smart chip related problems | Check smart chip recognition, remaining amount, information. |
501 | Nozzle 2 X-axis movement problem | Check motors and sensors |
502 | Y-axis movement problem | Check motors and sensors |
504 | Nozzle1 X-axis movement problem | Check motors and sensors |